dc.contributor.author | Baca Neglia, Máximo Fidel | |
dc.date.accessioned | 2016-07-21T14:07:02Z | |
dc.date.available | 2016-07-21T14:07:02Z | |
dc.date.issued | 2015 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12952/1008 | |
dc.description.abstract | Esta investigación nos permitió demostrar la capacidad del tratamiento físicoquímico para reducir el grado de contaminación de los efluentes generados en la industria de pinturas y de barnices, se utilizó dosis de: neutralizante coagulantes y floculantes ajustando el pH del efluente, previo a su tratamiento y que permitió a partir de su dosis optima reducir los valores de los indicadores de calidad que se hallaban por encima de los Valores Máximos Admisibles (VMA), del efluente industrial para su disposición final en el cuerpo receptor como lo dispone la legislación vigente. Se redujo primeramente la presencias de Grasas y Aceites inyectando aire a la muestra del efluente, logrando atrapar en la superficie de las burbujas de aire las (G y A), reduciendo un 64.17%, es decir: de 240 mg/L a 86 mg/L; para el caso de regular el pH, se utilizó neutralizante Soda Cáustica al 1 % (% en peso) para el efluente de pH ácido (4.7 unidades, encontrándose la dosis de 1.1 mL/L), logrando un valor de 7.00 (incrementándose en un 49%); adicionalmente se utilizó dosis de Coagulante MT - 8834 al 5% y de Floculante MT - 4285 al 0.05% (% en peso) obteniéndose los siguientes resultados: para la Demanda Bioquímica de Oxigeno (DBOs) de 76500 mg/L, se obtuvo VMA de 386.40 mg/L (reducción de 99.49 %); para la Demanda Química de Oxigeno (DQO), de 234060 mg/L se redujo a 845.32 mg/L (reducción de 99.64%); para los Sólidos Suspendidos Totales (SST) se logró una reducción del orden de 98.42%, es decir, de 4962 mg/L a 78.00 mg/L; para los Sólidos Sedimentados (SS) de 49.00 mL/L/h se redujo a 6.00 ml/L/h (reducción de 86.8%). Logrando un afluente apto para su disposición final al sistema de alcantarillado cumpliendo con DS N° 021 - 2009- VIVIENDA del 20.11.2009. | es_PE |
dc.description.abstract | This research allowed us to demonstrate the capacity of the physical - chemical
treatment to reduce the level of contamination of the effluents generated in the
industry of paints and varnishes, we used doses of neutralizing and coagulants
and flocculants, adjusting the pH of the effluent, prior to your treatment, and that
allowed from your dose optimal to reduce the values of indicators of quality that
were above the maximum admissible values (VMA), of industrial effluent
disposal in the water body as provided for in the legislation in force. Was first reduced the presence of Fats and Oils by injecting air to the sample of
the effluent, managing to catch on the surface of the bubbles of air the (F and
0), reducing a 64.17% i.e. 240 mg/L to 86 mg/L; in the case of regulating pH,
Caustic Soda was used as neutralizing 1% (% by weight) for the effluent from
the acidic pH (4.7 units, finding the dose of 1.1 mUL,), achieving a value of 7.00
(increasing by 49%); additionally we used doses of Coagulante MT- 8834, 5%
to dose flocculant MT - 8834, 0.05% (% by weight) obtained the following
results: for the Biochemical Demand of Oxygen (BDOs) which was initially
76500 mg/1, obtained a value of 386.40 mg/L (reduction of 99.49% ); for the
Chemical Demand of Oxygen (COD), a value 234030 mg/L was reduced to
845.32 mg/L (reduction of 99.64%); for Total Suspended Solids (TSS) achieved
a reduction in the order of 98.42% i.e., 4962 mg/L to 78.00 mg/L; for the
Sedimentad Solids (SS) of 49.00 mUUh was reduced to 6.00 mUUh (reduction
of 86.8%). Achieving an affluent suitable for disposal to the sewer system
complying with DS N° 021 - 2009- VIVIENDA of the November 20, 2009 | en_US |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional del Callao | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/pe/ | * |
dc.source | Universidad Nacional del Callao | es_PE |
dc.source | Repositorio institucional - UNAC | es_PE |
dc.subject | Physical - Chemical Treatment | es_PE |
dc.subject | Poyelectrolytes | es_PE |
dc.subject | Cationic | es_PE |
dc.subject | Anionic | es_PE |
dc.subject | Tratamiento físico- químico | es_PE |
dc.subject | Polielectrolitos | es_PE |
dc.subject | Catiónicos | es_PE |
dc.subject | Aniónicos | es_PE |
dc.title | El uso del tratamiento físico-químico para la depuración del efluente generado en una industria de pinturas y de barnices previos a su disposición final, ubicada en el distrito de Carabayllo - Lima | es_PE |
dc.type | info:eu-repo/semantics/report | es_PE |
dc.publisher.country | PE | es_PE |