dc.contributor.advisor | Flores Vega, Walter | |
dc.contributor.author | Atoche Medrano, Jason Jerry | |
dc.creator | Atoche Medrano, Jason Jerry | |
dc.date.accessioned | 2016-07-20T21:29:50Z | |
dc.date.available | 2016-07-20T21:29:50Z | |
dc.date.issued | 2010 | |
dc.identifier.other | T.530.A87 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12952/133 | |
dc.description.abstract | Las dosis impartidas a nvel del cristalino ocular y la tiroides son calculadas mediante simulación computacional en un fantoma de agua, para exposiciones de radiografía odontológica, considerándose para esto técnicas de exposición como el método de la bisectriz y de la perpendicular, así como también energías del haz de rayos -X con diferentes filtros de A1 (60 kV-1.5 mm A1, 70 kV-1.5 mm A1, 70 kV-2 mm A1). Utilizamos detectores termoluminiscentes (TLD) de floruro de litio (LiF) para calcular la dosis que llega al cristalino ocular y la tiroides. La simulación fue realizada mediante el código MCNP-4B. Los r.esultados obtenidos indican que existe una cantidad de dosis que recibe el cristalino ocular y la tiroides (desde 5% hasta un 31 % respecto a la dosis incidente). Lo cual indica que deben tomarse las medidas preventivas para evitar exponer innecesariamente a los órganos radio sensibles. Esta dosis encontrada varía con la dirección
del haz incidente y no supera el 35% de la dosis que produce el haz directo en un examen periapical. Hemos contrastado nuestros resultados con las mediciones que se hicieron a diferentes pacientes en el Hospital Daniel Alcides Carrión y La clínica Odontológica de la Universidad Nacional Mayor de San Marcos, observando gran similitud. | es_PE |
dc.description.abstract | The dose given level of the ocular crystalline lens and the thyroid are estimated by means of computational simulation in a fantoma of water, for expositions of X-ray picture odontology, considering to this techniques of exposition like the method of the bisectrix and the, perpendicular, as well energies of the bundle of X-xays- with different filters of Al (60kV-1.5 mm Al, 70 Kv-1.5 mm Al, 70 kV-2mm Al). We utilized detectors thermo luminescent (TLD) of Fluoride of Litio (LiF) to calculate the dose that gets to the ocular crystalline lens and the thyroid (from 5% to a 31% in relation to the incidental do se). The
simulation was accomplished by means of the code MCNP-4B. The obtained results suggest that exists a quantity of dose that receives the ocular crystalline lens and the thyroid. Which indicates that must take the preventive measures to avoíd the needlessly expose radio sensitive organs. This found dose varies with the incidental bundle's address and does not surpass 35% of the dose that produces the direct bundle in an .exam periapical. We have contrasted our results with the measurements that were done to different patients at the Daniel Alcides Carrion National Hospital and the Odontology Clinic of the Universidad Nacional Mayor de San Marcos, observing great similitude. | en_US |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional del Callao | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/pe/ | * |
dc.source | Universidad Nacional del Callao | es_PE |
dc.source | Repositorio institucional - UNAC | es_PE |
dc.subject | Exámen Dental | es_PE |
dc.subject | Montecarlo | es_PE |
dc.subject | Rayos X | es_PE |
dc.subject | Ocular | es_PE |
dc.subject | Dosimetria | es_PE |
dc.subject | Dental exam | es_PE |
dc.subject | X-Rays | es_PE |
dc.subject | Dosimetry | es_PE |
dc.title | Cálculo de dosis en el cristalino ocular en exámenes dentales utilizando simulación Monte Carlo | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
dc.publisher.country | PE | es_PE |