Mostrar el registro sencillo del ítem

dc.contributor.authorMANTARI, JOSÉ LUIS
dc.contributor.authorBONIFACIO, DIEGO
dc.contributor.authorHINOSTROZA, FANY PONCE
dc.contributor.authorPANDURO, ROY
dc.contributor.authorOLIDEN, JOSÉ
dc.contributor.authorCUBA, LIZBETH MÓNICA
dc.contributor.authorSALAZAR, JOSÉ LUIS
dc.contributor.authorTITO, JENNY
dc.contributor.authorGARCÍA, JORGE A.
dc.contributor.authorBENDEZÚ, MARÍA R.
dc.contributor.authorPARIONA-LLANOS, RICARDO
dc.contributor.authorAGUILAR-RAMIREZ, PRISCILIA
dc.contributor.authorALVARADO, ANGEL T.
dc.date.accessioned2025-02-28T20:39:55Z
dc.date.available2025-02-28T20:39:55Z
dc.date.issued2024
dc.identifier.issn4280296
dc.identifier.urihttps://hdl.handle.net/20.500.12952/9910
dc.description.abstractHIGH-FLOW NON-INVASIVE VENTILATION (NIV) DEVICES REDUCE THE MORBIDITY AND MORTALITY OF COVID-19. THE OBJECTIVE WAS TO EVALUATE THE USE OF THE NON-INVASIVE VENTILATION DEVICE WITH HIGH-FLOW HELMET CPAP DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19) HOSPITALIZED IN THE EMERGENCY SERVICES OF FIVE HOSPITALS. PROSPECTIVE MULTICENTER AND CROSS-SECTIONAL OBSERVATIONAL STUDY FROM FIVE HOSPITALS FROM JULY TO AUGUST 2020. 19 PATIENTS WERE RECRUITED AND DIVIDED INTO TWO GROUPS (G-1 N = 10; G-2 N = 9) APPLYING CLINICAL AND GASOMETRIC PARAMETERS AS INDICATORS OF DISEASE EVOLUTION UPON HOSPITAL ADMISSION AND WITHIN 24 HOURS. A PROGRESSIVE INCREASE IN THESE PARAMETERS WAS OBSERVED IN THOSE PATIENTS WHO USED THE NIV CPAP HELMET WITHIN THE FIRST 24 HOURS. IN G-01, IMPROVEMENT WAS EVIDENT IN 90% (N = 9/10): PAO2 (RANGE 48–137; AVERAGE: 82.49 ± 8.07; P-VALUE = 0.008), CO2 (25.2–51.0; 36.62 ± 2.62; P-VALUE P = 0.327), AND THE PAO2/FIO2 COEFFICIENT (87–318; 191.5 ± 18.68). 10% OF PATIENTS DID NOT PROGRESS OPTIMALLY, BEING SUBJECTED TO ENDOTRACHEAL INTUBATION AND INVASIVE MECHANICAL VENTILATION. IN G-02 THE VALUES WERE %SATO2 (RANGE 92–98; 96 ± 0.76) AND THE SAO2/FIO2 COEFFICIENT (214–228; 223.2 ± 1.80), INDICATING SIGNIFICANT IMPROVEMENT WITHIN 24 HOURS (P < 0.001). IT IS CONCLUDED THAT THE USE OF THE CPAP HELMET NON-INVASIVE VENTILATION (NIV) DEVICE CONTRIBUTES TO IMPROVING GASOMETRIC VALUES AND CLINICAL CONDITION. BEING AN ALTERNATIVE TO RECOVER TYPICAL CASES OF COVID-19 IN ALL HOSPITALS IN PERU. COPYRIGHT MANTARI JL ET AL. THIS IS AN OPEN ACCESS ARTICLE DISTRIBUTED UNDER THE TERMS OF THE CREATIVE COMMONS ATTRIBUTION LICENSE (CC-BY 4.0), WHICH PERMITS UNRESTRICTED USE, DISTRIBUTION, AND REPRODUCTION IN ANY MEDIUM, PROVIDED THE ORIGINAL AUTHOR AND SOURCE ARE CREDITED.
dc.formatapplication/pdf
dc.language.isospa
dc.publisherPHARMACIA
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectCOVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORTes_PE
dc.titleUSE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDYes_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.identifier.doi10.3897/PHARMACIA.71.E135653
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.00.00es_PE